Login
Close

Login



PVMax Scanner Attachment Cords

 

PVMax Scanners are connected to the broad range of the RiT SMART Patch Panel with Round Attachment Cords:

  • Supplied in various lengths
  • Several types of Round Attachment Cords are available to fit the various types of SMART Patch Panels
    

 

There are three different methods available to connect Patch Panels to PVMax Scanners.  

1. The first method uses one of two different types of Scanner Attachment Cords. These are Group A and Group B. One end of the attachment cord is connected directly to the PVMax Scanner and the other end/s to the Patch Panel. This method allows a maximum of 12 Panels to be connected to each Scanner. 

Group A 

Each port of the PVMax Scanner is connected to a Patch Panel using a Scanner Attachment Cord with one 26-pin connector on each end. 

Group B 

Each port of the PVMax Scanner is connected to a Patch Panel using a Scanner Attachment Cord with a 26-pin connector on the Scanner end and two 14-pin connectors on the Patch Panel end. 

2. The Second method uses the PVMax Splitter. The Splitter doubles the functionality of the PVMax Scanner, allowing up to 24 Panels to be connected to each Scanner. Both types can be connected to the Splitter as shown in the next two diagrams. 

Splitter Attachment Cord 

The connection between the Scanner and the Splitter can be made either with the regular Group A Scanner Attachment Cord or with the Splitter Attachment Cord, which is a short Group A Cord. 

Group A

Each PVMax Splitter is connected on one side to one port of the PVMax Scanner and on the other side to two Patch Panels  using two Group A Scanner Attachment Cords.  

SMART Giga 24 Patch Panel example 

 

 

 

Group B

Each PVMax Splitter is connected on one side to one port of the PVMax Scanner and on the other side to two Patch Panels  using two Group B Scanner Attachment Cords. 

SMART CLASSix 24 Patch Panel example:

 

 

 

 

 

3. The third method uses PVMax Panels. 

The PVMax Panels have been designed to work exclusively with the PVMax system without having to use Splitters. This method has the same functionality as the second method but it enables cutting by half the number of Scanner Attachment Cords required per installation.  

In general all the panels are connected with Group B Scanner Attachment Cords. The top patch panel should connect to scanner connector 1A, the next panel to connector 1B and then 2A, 2B etc. 

SMART CLASSix Panel, 24, PVMax 

Each connector of the PVMax Scanner is connected to a PVMax Panel using a Group B Scanner Attachment Cord with a 26-pin connector on the Scanner end and two 14-pin connectors on the two PVMax Panel ends.  

As seen in the following diagram, one Group B Scanner Attachment Cord connects 2 PVMax Panels to one connector in the Scanner.

 

 

 

 

SMART CLASSix Panel, 48, PVMax 

Each connector of the PVMax Scanner is connected to a PVMax Panel using a Group B Scanner Attachment Cord with a 26-pin connector on the Scanner end and two 14-pin connectors on the PVMax Panel end.  

As seen in the following diagram, one Group B Scanner Attachment Cord connects one PVMax Panel to one connector in the Scanner

 

 

 

 



Scanner Attachement Cord Configuration Table - Group A

 

Scanner Attachement Cord Configuration Table - Group B

Number Description

Round Scanner Attachment Cord, Group B, UTP

R3844015

Round Scanner Attachment Cord, Group B, UTP, LSZH, 1.5m

R3844025

Round Scanner Attachment Cord, Group B, UTP, LSZH, 2.5m

R3844040

Round Scanner Attachment Cord, Group B, UTP, LSZH, 4.0m

R3844050

Round Scanner Attachment Cord, Group B, UTP, LSZH, 5.0m

R3844060

Round Scanner Attachment Cord, Group B, UTP, LSZH, 6.0m

Round Scanner Attachment Cord, Group A, UTP

R3818015

Round Scanner Attachment Cord, Group A, UTP, 1.5m

R3818025

Round Scanner Attachment Cord, Group A, UTP, 2.5m

R3818060

Round Scanner Attachment Cord, Group A, UTP, 6.0m

R3818120

Round Scanner Attachment Cord, Group A, UTP, 12.0m

 

* Power cord (C13) is not included


Contact Us
Please fill in your details and our staff will contact you.
*
*
*
*
*
*
*Required
*Enter the below security code here

Refresh
Close

GUI: Grid_1.asp
close